Vacuum FTIR Vertex70v + microscope Hyperion 3000 KIT - polarizors (FTIR)

Vacuum FTIR Vertex70v + microscope Hyperion 3000 KIT - polarizors
CONTACT US

Guarantor: Alois Nebojsa
Technology / Methodology: Optical measurements
Instrument status: Some Issues Some Issues, 12.8.2021 10:13, Beamsplitter Myllar (FIR) is out of order
Research group: CF: CEITEC Nano


Detailed description:

Instrument consists of a combination of Fourier infrared spectrometer with infrared microscope. In the spectrometer, one can perform transmission and reflection experiments on samples dimension of roughly 1 mm2 and more in the full frequency range offered by the spectrometer, 30-14 000 cm-1. The microscope is used for measurements of either small or spatially inhomogeneous samples essentially down to the diffraction limit in the far field, it means roughly 3 at 3000 cm-1. The frequency range is however limited by the microscope detectors to 600-6000 cm-1. The highlight of this microscope is the focal plane array (FPA) detector that allows simultaneous recording of 128x128 matrix of spectra in the frequency range 900-5000 cm-1.


Publications:

  • KASPAR, P.; SOBOLA, D.; ČÁSTKOVÁ, K.; DALLAEV, R.; ŠŤASTNÁ, E.; SEDLÁK, P.; KNÁPEK, A.; TRČKA, T.; HOLCMAN, V., 2021: Case Study of Polyvinylidene Fluoride Doping by Carbon Nanotubes. MATERIALS 14(6), p. 1428-1 - 12, doi: 10.3390/ma14061428; FULL TEXT
    (RIGAKU3, VERIOS, WITEC-RAMAN, KRATOS-XPS, FTIR)
  • OLIVER, C.; IBANEZ, R.; FLORES-MERINO, M.; VOJTOVÁ, L.; ŠALPLACHTA, J.; ČELKO, L.; KAISER, J.; MONTUFAR JIMENEZ, E., 2021: Lyophilized Polyvinylpyrrolidone Hydrogel for Culture of Human Oral Mucosa Stem Cells. MATERIALS 14(1), p. 1 - 14, doi: 10.3390/ma14010227; FULL TEXT
    (FTIR, WITEC-RAMAN, LYRA)
  • Michlicek, M; Blahova, L; Dvorakova, E; Necas, D; Zajickova, L, 2021: Deposition penetration depth and sticking probability in plasma polymerization of cyclopropylamine. APPLIED SURFACE SCIENCE 540, doi: 10.1016/j.apsusc.2020.147979; FULL TEXT
    (WOOLLAM-VIS, LYRA, FTIR, KRATOS-XPS)
  • Mohelský, I., 2020: Infrared magneto–spectroscopy of Bi2Te3 topological insulator. MASTER´S THESIS , p. 1 - 49
    (FTIR, WOOLLAM-MIR, MAGNETRON, CRYOGENIC, KRATOS-XPS)
  • GHOSH, K.; NG, S.; IFFELSBERGER, C.; PUMERA, M., 2020: Inherent impurities in graphene/polylactic acid filament strongly influence on the capacitive performance of 3D-printed electrode. CHEMISTRY-A EUROPEAN JOURNAL 26(67), p. 15746 - 8, doi: 10.1002/chem.202004250; FULL TEXT
    (VERIOS, KRATOS-XPS, WITEC-RAMAN, FTIR, RIGAKU3)

Show more publications...